We – EPG Team the greatest gearbox & motors , couplings and gears manufacturing facility in China with 5 distinct branches. For much more specifics: Cell/whatsapp/telegram/Kakao us at: 0086~13083988828 13858117778083988828
2.1 Naming and nameplate identification
2.1.1 Naming rule
JAC200 4KW
Identification | Voltage stage |
four | three-section 380V |
S2 | One-stage 220V |
Identification | Adaptive motor sort |
G | Basic type |
Identification | .4 | .seventy five | … | four hundred |
Adaptive motor(KW) | .4 | .75 | … | 400 |
2.2 Introduction of different parts of the converter
The framework types of JAC580N sequence converter are the plastic and metal. The external diagram is revealed underneath.
2.3 Fundamental technological specification
Desk 2-1 Technical specification of 580N sequence frequency converter
Item | Specification | ||
Standard capabilities | Greatest frequency | Vector handle: ~500Hz V/F management: ~500Hz | |
Carrier frequency | 0.8kHz~12kHz The provider frequency is automatically altered based mostly on the load characteristics. |
||
Input frequency resolution |
Digital location: .01Hz Analog location: highest frequency x .571% |
||
Control mode | • Open up-loop vector handle (SVC) • Shut-loop vector control (FVC) • Voltage/Frequency (V/F) management |
||
Starting up torque | • G type: .5 Hz/a hundred and fifty% (SVC) Hz/a hundred and eighty% (FVC) • P type: .5 Hz/100% |
||
Basic features | Velocity range | one:one hundred (SVC) | 1:a thousand (FVC) |
Consistent-pace precision | ± .5% (SVC) | ± .02% (FVC) | |
Overload potential | • G type:60s for one hundred fifty% of the rated recent • P kind: 60s for 120% of the rated current. |
||
Torque improve | • Mounted increase • Custom-made boost .1%-thirty.% |
||
V/F curve | • Straight-line V/F curve • Multi-position V/F curve •N-power V/F curve (1.2-power, 1.4-electricity, 1.6-electrical power, ,1.8-electrical power, square) |
||
V/F separation | Two types: full separation half separation | ||
Acceleration /deceleration curve | • Straight-line ramp • S-curve ramp 4 teams of acceleration/deceleration time with the selection of .-6500.0s |
||
DC bra ept | DC bra ept frequency: .00Hz~optimum frequency Bra ept time: .0s~36.0s Bra ept motion existing worth: .%-one hundred.% |
||
JOG manage | JOG frequency assortment: .00-50.00 Hz JOG acceleration/deceleration time: .-6500.0s |
||
Operation | Command supply | Operation panel, control terminal and serial interaction port are given Change in numerous methods |
|
Frequency resource | Various frequency resources: electronic reference, analog voltage reference, analog recent reference, pulse reference and serial port reference. The switching can be performed in different approaches | ||
Auxiliary frequency resource | 10 kinds of auxiliary frequency supply. The auxiliary frequency jog and frequency synthesis can be reached flexibly | ||
Input terminal | Standards: 7 digital input terminals, amid which one help optimum higher-velocity pulse enter of 100kHz 2 analog input terminals, among which a single only supports voltage input of ~10V and the other supports voltage input of ~10V or recent input of 4 ~20mA Expansion capability: three electronic enter terminals 1 analog input terminal, which supports voltage input of -10V ~10V and supports PT100/PT1000 |
||
Output terminal | Standards: 1 substantial-speed pulse output terminal (The open collector kind is optional), supporting ~100kHz sq. sign output one electronic output terminal one relay output terminal 1 analog output terminal, supporting present output of ~20mA or voltage output of ~10V Expansion capability: one electronic output terminal one relay output terminal 1 analog output terminal, supporting existing output of ~20mA or voltage output of ~10V |
||
Display and keyboard operation | LED exhibit | Display the parameter | |
Crucial lock and operate variety | Realize partial or all important lock and define the action selection of some keys to avoid misoperation | ||
Safety operate | Short circuit check of electrified motor, enter/output default stage security, overcurrent safety, overvoltage safety, undervoltage defense, overheat protection, overload defense, etc. |
The use of authentic equipment manufacturer’s (OEM) portion figures or trademarks , e.g. CASE® and John Deere® are for reference purposes only and for indicating item use and compatibility. Our business and the detailed substitute elements contained herein are not sponsored, accepted, or created by the OEM.